Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Clin Oncol (R Coll Radiol) ; 35(5): e312-e318, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36804153

RESUMO

AIMS: Intrahepatic cholangiocarcinoma (iCCA) and hepatocellular carcinoma (HCC) differ in prognosis and treatment. We aimed to non-invasively differentiate iCCA and HCC by means of radiomics extracted from contrast-enhanced standard-of-care computed tomography (CT). MATERIALS AND METHODS: In total, 94 patients (male, n = 68, mean age 63.3 ± 12.4 years) with histologically confirmed iCCA (n = 47) or HCC (n = 47) who underwent contrast-enhanced abdominal CT between August 2014 and November 2021 were retrospectively included. The enhancing tumour border was manually segmented in a clinically feasible way by defining three three-dimensional volumes of interest per tumour. Radiomics features were extracted. Intraclass correlation analysis and Pearson metrics were used to stratify robust and non-redundant features with further feature reduction by LASSO (least absolute shrinkage and selection operator). Independent training and testing datasets were used to build four different machine learning models. Performance metrics and feature importance values were computed to increase the models' interpretability. RESULTS: The patient population was split into 65 patients for training (iCCA, n = 32) and 29 patients for testing (iCCA, n = 15). A final combined feature set of three radiomics features and the clinical features age and sex revealed a top test model performance of receiver operating characteristic (ROC) area under the curve (AUC) = 0.82 (95% confidence interval =0.66-0.98; train ROC AUC = 0.82) using a logistic regression classifier. The model was well calibrated, and the Youden J Index suggested an optimal cut-off of 0.501 to discriminate between iCCA and HCC with a sensitivity of 0.733 and a specificity of 0.857. CONCLUSIONS: Radiomics-based imaging biomarkers can potentially help to non-invasively discriminate between iCCA and HCC.


Assuntos
Neoplasias dos Ductos Biliares , Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Colangiocarcinoma/diagnóstico por imagem , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos/patologia
2.
Eur J Radiol ; 159: 110681, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36592582

RESUMO

PURPOSE: To evaluate the clinical applicability of a prototype virtual non-contrast (VNC) reconstruction algorithm based on coronary CT angiography (cCTA) to assess calcified coronary plaques by calcium scoring (CACS). METHODS: Eighty consecutive patients suspected of coronary artery disease were retrospectively included. All patients underwent a cardiac CT using a dual-layer spectral-detector CT system. The standardized acquisition protocol included unenhanced CACS and cCTA. Datasets were acquired using 120 keV. VNC-reconstructions were calculated from the cCTA images at 2.5 mm (VNC group 1), 2.5 of 0.9 mm (group 2), and 0.9 mm (group 3) slice thickness. We compared the Agatston score and Coronary Artery Calcium Data and Reporting System (CAC-DRS) of all VNC reconstructions with the true non-contrast (TNC)-dataset as the gold standard. RESULTS: In total, 73 patients were evaluated. Fifty patients (68.5 %) had a CACS > 0 based on TNC. We found a significant difference in the Agatston score comparing all VNC-reconstructions (1: 1.35, 2: 3.7, 3: 10.4) with the TNC dataset (3.8) (p < 0.001). Correlation analysis of the datasets showed an excellent correlation of the TNC results with the different VNC-reconstructions (r = 0.904-0.974, p < 0.001) with a slope of 1.89-2.53. Mean differences and limits of agreement by Bland-Altman analysis between TNC and group 1 were 83 and -196 to 362, respectively. By using the VNC-reconstructions, in group 1 23 patients (31.5 %), in group 2 10 (13.7 %), and in group 3 23 (31.5 %) were reclassified according to CAC-DRS compared to TNC. Classification according to CAC-DRS revealed a significant difference between TNC and group 1 (p = 0.024) and no significance compared to groups 2 and 3 (p = 0.670 and 0.273). CONCLUSION: The investigated VNC reconstruction algorithm of routine cCTA allows the detection and evaluation of coronary calcium burden without the requirement for an additional acquisition of an unenhanced CT scan for CACS and, therefore, a reduction of radiation exposure.


Assuntos
Cálcio , Tomografia Computadorizada por Raios X , Humanos , Cálcio/análise , Estudos Retrospectivos , Estudos de Viabilidade , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos
3.
Clin Radiol ; 71(1): e11-5, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26521185

RESUMO

AIM: To evaluate the advantage of sinogram-affirmed iterative reconstruction (SIR) compared to filtered back projection (FBP) in upper abdomen computed tomography (CT) after transarterial chemoembolisation (TACE) at different tube currents. MATERIALS AND METHODS: The study was approved by the institutional review board. Written informed consent was obtained from all patients. Post-TACE CT was performed with different tube currents successively varied in four steps (180, 90, 45 and 23 mAs) with 40 patients per group (mean age: 60±12 years, range: 23-85 years, sex: 70 female, 90 male). The data were reconstructed with standard FBP and five different SIR strengths. Image quality was independently rated by two readers on a five-point scale. High (Lipiodol-to-liver) as well as low (liver-to-fat) contrast-to-noise ratios (CNRs) were intra-individually compared within one dose to determine the optimal strength (S1-S5) and inter-individually between different doses to determine the possibility of dose reduction using the Kruskal-Wallis test. RESULTS: Subjective image quality and objective CNR analysis were concordant: intra-individually, SIR was significantly (p<0.001) superior to FBP. Inter-individually, regarding different doses (180 versus 23 ref mAs), there was no significant (p=1.00) difference when using S5 SIR at 23 mAs instead of FBP. CONCLUSION: SIR allows for an 88% dose reduction from 3.43 to 0.4 mSv in unenhanced CT of the liver following TACE without subjective or objective loss in image quality.


Assuntos
Quimioembolização Terapêutica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Óleo Etiodado/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação
4.
AJNR Am J Neuroradiol ; 37(1): 143-50, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26427836

RESUMO

BACKGROUND AND PURPOSE: Dose-saving techniques in neck CT cause increased image noise that can be counteracted by iterative reconstruction. Our aim was to evaluate the image quality of advanced modeled iterative reconstruction (ADMIRE) in contrast-enhanced low-tube-voltage neck CT. MATERIALS AND METHODS: Sixty-one patients underwent 90-kV(peak) neck CT by using third-generation 192-section dual-source CT. Image series were reconstructed with standard filtered back-projection and ADMIRE strength levels 1, 3, and 5. Attenuation and noise of the sternocleidomastoid muscle, internal jugular vein, submandibular gland, tongue, subscapularis muscle, and cervical fat were measured. Signal-to-noise and contrast-to-noise ratios were calculated. Two radiologists assessed image noise, image contrast, delineation of smaller structures, and overall diagnostic acceptability. Interobserver agreement was calculated. RESULTS: Image noise was significantly reduced by using ADMIRE compared with filtered back-projection with the lowest noise observed in ADMIRE 5 (filtered back-projection, 9.4 ± 2.4 Hounsfield units [HU]; ADMIRE 1, 8.3 ± 2.8 HU; ADMIRE 3, 6.7 ± 2.0 HU; ADMIRE 5, 5.4 ± 1.7 HU; all, P < .001). Sternocleidomastoid SNR and internal jugular vein-sternocleidomastoid contrast-to-noise ratios were significantly higher for ADMIRE with the best results in ADMIRE 5 (all, P < .001). Subjective image quality and image contrast of ADMIRE 3 and 5 were consistently rated better than those for filtered back-projection and ADMIRE 1 (all, P < .001). Image noise was rated highest for ADMIRE 5 (all, P < .005). Delineation of smaller structures was voted higher in all ADMIRE strength levels compared with filtered back-projection (P < .001). Global interobserver agreement was good (0.75). CONCLUSIONS: Contrast-enhanced 90-kVp neck CT is feasible, and ADMIRE 5 shows superior objective image quality compared with filtered back-projection. ADMIRE 3 and 5 show the best subjective image quality.


Assuntos
Algoritmos , Meios de Contraste , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Pescoço/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
5.
Clin Radiol ; 70(8): e67-73, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26050533

RESUMO

AIM: To evaluate neck computed tomography (CT) with a reduced tube voltage of 80 kVp in patients with suspected peritonsillar abscess (PTA) regarding objective and subjective image quality, and the potential for dose reduction. MATERIALS AND METHODS: Forty-seven patients with clinically suspected PTA were retrospectively analysed. Patients were examined using dual-source CT in dual-energy mode. The objective and subjective image quality of 80 kVp images were compared with linearly blended 120 kVp images (M_0.3; 30% of 80 kV, 70% of 140 kV spectrum). Attenuation of abscess rim enhancement, central necrosis, and several other anatomical landmarks were measured. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and rim-to-abscess CNR (raCNR) were calculated. Radiation dose was assessed as size-specific dose estimates (SSDE). Subjective image quality was assessed according to the European guidelines on quality criteria for CT. Interobserver agreement was calculated using the intraclass correlation coefficient (ICC). RESULTS: Attenuation of inflamed soft tissue (141.7 ± 16.3 versus 93.7 ± 9.3 HU, p < 0.001), CNR (9.6 ± 4.8 versus 5.6 ± 3.8, p = 0.001), raCNR (14.3 ± 5.9 versus 12.4 ± 4.4, p = 0.02), and subjective image sharpness (3.6 ± 0.6 versus 2.8 ± 0.7, p < 0.001) were significantly increased in the 80 kVp compared to 120 kVp, whereas subjective and objective image noise were significantly increased with 80 kVp acquisition (p < 0.001). Overall interobserver agreement was almost perfect (ICC, 0.87). Calculated SSDE of 80 kVp acquisition was decreased by 49.7% compared to 120 kVp (10.58 ± 0.76 versus 21.04 ± 1.43 mGy, p < 0.001). CONCLUSION: Low-tube-voltage 80 kVp neck CT provides increased enhancement of soft-tissue inflammation, CNR, raCNR, and improved abscess delineation in patients with PTA compared to standard 120 kVp acquisition while resulting in a significant reduction of radiation exposure.


Assuntos
Abscesso Peritonsilar/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
6.
Clin Radiol ; 70(2): 168-75, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25491926

RESUMO

AIM: To compare non-linear and linear image-blending post-processing techniques in dual-energy CT (DECT) of primary head and neck squamous cell carcinoma (SCC) regarding subjective and objective image quality. MATERIALS AND METHODS: Head and neck DECT studies from 69 patients (48 male, 21 female; mean age 62.3 years) were retrospectively evaluated. All tumour lesions were histologically confirmed SCC. Linearly blended 80/140 kVp images series with varying weighting factors of 0.3 (M_0.3), 0.6 and 0.8 were compared with non-linearly blended images. Attenuation of tumour lesion, various soft-tissue structures, the internal jugular vein, and image noise were measured, tumour signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Overall image quality, delineation of tumour lesion, image sharpness, and noise level were rated individually by three radiologists using five-point Likert scales. Interobserver agreement was calculated using intraclass correlation coefficient (ICC). RESULTS: Enhancement of tumour lesions (non-linear, 137.5 ± 20.1 HU; M_0.3, 92.7 ± 14.4 HU; M_0.6, 110 ± 15.4 HU; M_0.8, 123 ± 18.2 HU), CNR (non-linear, 12 ± 8; M_0.3, 4 ± 4.7; M_0.6, 7.5 ± 5.5; M_0.8, 8 ± 5.5), subjective overall image quality and tumour delineation were significantly increased (all p < 0.001) with the non-linear blending technique compared to all investigated linear blending weighting factors. Overall interobserver agreement was substantial (ICC 0.70; 95% CI: 0.66-0.73). CONCLUSION: Post-processing of DECT using a non-linear blending technique provides improved objective and subjective image quality of head and neck SCC compared to linearly blended images series.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído
7.
AJNR Am J Neuroradiol ; 35(12): 2376-81, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25104285

RESUMO

BACKGROUND AND PURPOSE: Low-tube-voltage acquisition has been shown to facilitate substantial dose savings for neck CT with similar image contrast compared with standard 120-kVp acquisition. However, its potential for the detection of neck pathologies is uncertain. Our aim was to evaluate the effects of low-tube-voltage 80-kV(peak) acquisitions for neck CT on diagnostic accuracy and interobserver agreement. MATERIALS AND METHODS: Three radiologists individually analyzed 80-kVp and linearly blended 120-kVp image series of 170 patients with a variety of pathologies who underwent dual-energy neck CT. Reviewers were unblinded to the clinical indication for CT but were otherwise blinded to any other data or images and were asked to state a final main diagnosis. Findings were compared with medical record charts, CT reports, and pathology results. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for each observer. Interobserver agreement was evaluated by using intraclass correlation coefficients. RESULTS: Diagnoses were grouped as squamous cell carcinoma-related (n = 107, presence/absence of primary/recurrent squamous cell carcinoma), lymphoma-related (n = 40, presence/absence of primary/recurrent lymphoma), and benign (n = 23, eg, abscess). Cumulative sensitivity, specificity, positive predictive value, and negative predictive value for 80-kVp and blended 120-kVp images were 94.8%, 93.0%, 95.9%, and 91.1%, respectively. Results were also consistently high for squamous cell carcinoma-related (94.8%/95.3%, 89.1%/89.1%, 94.3%/94.4%, 90.1%/91.0%) and lymphoma-related (95.0%, 100.0%, 100.0%, 95.2%) 80-kVp/120-kVp image series. Global interobserver agreement was almost perfect (intraclass correlation coefficient, 0.82, 0.80; 95% CI, 0.76-0.74, 0.86-0.85). Calculated dose-length product was reduced by 48% with 80-kVp acquisitions compared with the standard 120-kVp scans (135.5 versus 282.2 mGy × cm). CONCLUSIONS: Low-tube-voltage 80-kVp CT of the neck provides sufficient image quality with high diagnostic accuracy in routine clinical practice and has the potential to substantially decrease radiation exposure.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Variações Dependentes do Observador , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Abscesso/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Sensibilidade e Especificidade , Adulto Jovem
8.
Rofo ; 186(10): 937-44, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24729409

RESUMO

PURPOSE: Chemosaturation with percutaneous hepatic perfusion (PHP; Hepatic CHEMOSAT(®) Delivery System; Delcath Systems Inc, USA) is a minimally invasive, repeatable regional therapy for unresectable hepatic metastases. It uses a system of catheters and filters to isolate hepatic venous blood from the systemic circulation, allowing delivery of high-dose chemotherapy to the hepatic artery. Effluent hepatic venous blood is filtered before being returned to the systemic circulation, thereby reducing exposure to chemotherapy. We describe our experiences with chemosaturation-PHP at 2 European centers. MATERIALS AND METHODS: 14 patients presented unresectable hepatic metastases from solid tumors; 13 received 1 - 3 sessions of chemosaturation-PHP. Melphalan 2.0 (n = 1) or 3.0 (n = 12) mg/kg was given as a 30-minute infusion into the hepatic artery. 12 patients were evaluable for tumor response. RESULTS: One complete (cholangiocarcinoma, n = 1) and 6 partial responses (ocular, n = 3 or cutaneous melanoma, n = 3) were observed, 5 patients had stable disease (ocular melanoma, n = 3; breast cancer, n = 1; gastric cancer, n = 1). Mild to moderate filter-related toxicity (i. e. thrombocytopenia, anemia) was observed immediately post-procedure. Grade 3/4 melphalan-related pancytopenia developed after 1 - 2 weeks. All hematological events were managed effectively with transfusions and/or other supportive measures. The new high-efficiency filter showed milder toxicity and faster recovery. In one case, chemosaturation-PHP was abandoned prematurely due to heparin-induced vaginal bleeding, and one patient died due to retroperitoneal hemorrhage from heparin anti-coagulation. CONCLUSION: Chemosaturation-PHP for non-resectable liver metastases is a feasible treatment option when performed by an experienced multi-disciplinary team. It may be a promising regional therapy for patients with no effective treatment options.


Assuntos
Quimioterapia do Câncer por Perfusão Regional/instrumentação , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/secundário , Melfalan/administração & dosagem , Adulto , Idoso , Relação Dose-Resposta a Droga , Desenho de Equipamento , Europa (Continente) , Feminino , Filtração/instrumentação , Seguimentos , Humanos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Masculino , Melfalan/efeitos adversos , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X
9.
S Afr Med J ; 64(23): 891-3, 1983 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-6635889

RESUMO

Hepatitis B markers were determined by radioimmunoassay of serum samples from 1 495 Black subjects representative of the resident population of Kangwane, a rural area with a high incidence of chronic liver disease and hepatocellular carcinoma. Pregnant women formed an important part of the study group, since it was intended to assess the frequency of perinatal transmission and the passive immunity of their infants, two factors which would markedly influence an infant immunization programme. A high overall marker positivity rate was found, indicating that hepatitis B is endemic. The hepatitis B surface antigen (HBsAg) carrier rate was 14,6% in adult males and 4,6% in adult females, while 82.6% of adult males and 69,4% of adult females were positive for at least one marker, indicating that infection had been present at some stage. Of infants under 1 year of age 34,5% were positive for antibodies to HBsAg (anti-HBs), compared with 9,3% at 13-24 months, which indicates that transplacental transfer of anti-HBs is frequent. Other markers were acquired even in the 1st year of life, with the sharpest increase at 3-11 years. Perinatal transmission was not common, however, and horizontal transmission during early childhood seemed to play an important role. It was concluded that the risk and frequency of infection justified a vaccine trial in this population and that the target group for vaccination should be infants under 1 year of age.


Assuntos
Antígenos de Superfície da Hepatite B/análise , Vírus da Hepatite B/imunologia , Hepatite B/epidemiologia , Vacinas Virais/uso terapêutico , Adolescente , Adulto , Negro ou Afro-Americano , Fatores Etários , População Negra , Criança , Pré-Escolar , Feminino , Hepatite B/imunologia , Hepatite B/prevenção & controle , Humanos , Lactente , Masculino , Troca Materno-Fetal , Gravidez , Fatores Sexuais , África do Sul , Vacinação
10.
J Infect ; 7 Suppl 1: 53-5, 1983 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-6674370

RESUMO

Three injections of 10 microgram/ml hepatitis B vaccine (Merck) given in the first week after birth, a month later and again at the age of six months to 63 neonates in a rural African population, elicited an antibody response in 93 per cent. The initial hepatitis B marker status of the babies and mothers did not influence the results at nine months. Side-effects were minor and we conclude that the vaccine can effectively and safely be used from birth in endemic situations.


Assuntos
Anticorpos Anti-Hepatite B/análise , Vírus da Hepatite B/imunologia , Recém-Nascido , Vacinas Virais/uso terapêutico , Feminino , Hepatite B/prevenção & controle , Humanos , Lactente , Masculino , África do Sul , Vacinação , Vacinas Virais/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...